MLF supplies waterproof IP44 power adpater , Ip44 ac adapter mostly used for outdorr device as portable lighting, LED camping lamp , LED flashlight, LED signal lamp, emergency lighting, garden landscap lamp and many kinds of other outdoor lightings .The main items we made are 5V1A ,5V2A 9V1A ,12V2A ,12V3A ,12V5A etc ,which are compliance with EN61347 safety and EMC standard , quality is reliable.two years quality warranty is acceptable .MLF is also willing to do custom design and advise technology solution to our customers. Welcome to inquiry us about any questions about waterproof switching power adapter! Waterpoof Power Adpater,Waterproof 12V Power Adapter,Waterproof AC Adapter,Waterproof Plug Adapter,Wapterproof USB Adapter,IP44 AC DC Adapter Meile Group Limited , http://www.hkmeile.com
33KV Compacted Round Copper Conductor Nylon anti-termite HDPE Cable,AS/NZS standard
Description 35KV Compacted Round Copper Conductor Double Steel Tape Armoured Cable
Construction: Compacted stranded circular copper conductor, extruded semi-conducting compound as conductor shield, cross-linked polyethylene (XLPE) insulation, semi-conducting compound as insulation shield, copper tape or combination of copper wire and tape as metallic screen, three cores assembled together with non-hygroscopic polypropylene filler, wrapped with binder tape, PVC inner covering as armoring bedding, galvanized steel tape armored, PVC outer sheath.Â
2.Operating CharacteristicsÂ
Rated voltage U0/U(Um): 26/35(40.5)kVÂ
U0 is the rated power frequency voltage between conductor and earth or metallic screen for which the cable is designed;Â
U is the rated power frequency voltage between conductors for which the cable is designed;Â
Um is the maximum value of the "highest system voltage" for which the equipment may be used.Â
Max. permissible continuous operating temperature of conductor: 90 °CÂ
Max. temperature of conductor during short-circuit (5s max. duration) shall not exceed: 250 °CÂ
The ambient temperature under installation should not be lower than: 0 °CÂ
The bending radius of cable is recommended as following:Â
For single core cable: not less than 20 times of the diameter of cableÂ
For three core cable: not less than 15 times of the diameter of cableÂ
3.ApplicationÂ
The cable is used for fixed installations such as electric power distribution networks or industrial installations, which is laid indoors, outdoors, in tunnel or in cable trench, unable to bear external mechanical force.Â
Single core cable in magnetic duct is not permissible.Â
4.Main technical data of 26/35KV, three cores, Copper conductor, XLPE insulated, galvanized steel wire armored and PVC or PE sheath cable
Size
Â
Nominal thickness of XLPE insulation(mm)
Â
Approx. thickness of copper tape screen (mm)
Â
Approx. diameter of steel wire (mm)
Â
Nominal thickness of PVC or PE(mm)
Â
Approx. overall diameter of finished cable(mm)
Â
Max. conductor D.C resistance @ 20 0 C (Ω/km)
Â
3x50mm 2
Â
10.5
Â
0.10
Â
3.15
Â
3.8
Â
92.3
Â
0.387
Â
3x70mm 2
Â
10.5
Â
0.10
Â
3.15
Â
3.9
Â
96.4
Â
0.268
Â
3x95mm 2
Â
10.5
Â
0.10
Â
3.15
Â
4.1
Â
100.4
Â
0.193
Â
3x120mm 2
Â
10.5
Â
0.10
Â
3.15
Â
4.2
Â
103.8
Â
0.153
Â
3x150mm 2
Â
10.5
Â
0.10
Â
3.15
Â
4.3
Â
107.8
Â
0.124
Â
3x185mm 2
Â
10.5
Â
0.10
Â
3.15
Â
4.4
Â
111.5
Â
0.0991
Â
3x240mm 2
Â
10.5
Â
0.10
Â
3.15
Â
4.6
Â
117.3
Â
0.0754
Â
3x300mm 2
Â
10.5
Â
0.10
Â
3.15
Â
4.7
Â
122.1
Â
0.0601
Â
3x400mm 2
Â
10.5
Â
0.10
Â
3.15
Â
5.0
Â
130.0
Â
0.0470
January 07, 2019