Model NO.: HV cable
Wire Core Material: Bare Copper Wire
Certification: ISO, CCC
Model: Yjlw02-Z Yjlw03-Z Yjq02-Z Ujq03-Z
Size(mm2): ......95.120 185, 240,300,400, 500, 630,800,1000
Produceing Experience: 15 Years
OEM: Yes
Specification: SGS CCC IEC
Origin: Henan
Model NO.: HV cable
Wire Core Material: Bare Copper Wire
Certification: ISO, CCC
Model: Yjlw02-Z Yjlw03-Z Yjq02-Z Ujq03-Z
Size(mm2): ......95.120 185, 240,300,400, 500, 630,800,1000
Produceing Experience: 15 Years
OEM: Yes
Specification: SGS CCC IEC
Origin: Henan
66kV 110kV 220kV HV Cable- 

1.Cable Description:
Single core,Copper conductor, XLPE insulation,Corrugated Aluminum sheath, or lead alloy sheath, or Copper wire Screen,PVC or PE Outer sheath power cable


2.Cable property:

1)The maximum rated working temperature of conductor is 90°C, and the maximum temperature is less than 250°C when short circuit occurs(no more than 5 seconds
2)
Allowable maximum lateral pressure is 5KN/m.
3)
Allowable maximum traction strength of aluminum conductor is 40N/mm2.
4)Cable laying temperature is not less than 0°C.
5)The minimum bending radius is no less than 20D.

          (D---represents actual outer diameter of cable)

3.Type and Application:

66kv 110kv 220kv XLPE Insulated Hv Cable

4.Structure Drawing
66kv 110kv 220kv XLPE Insulated Hv Cable



5.Size range we produce:
66kv 110kv 220kv XLPE Insulated Hv Cable
6.Packing:
   Wooden Drum, Steel Wooden Drum, All Steel Drum for very heavy cable
66kV 110kV 220kV HV Cable- 

1.Cable Description:
Single core,Copper conductor, XLPE insulation,Corrugated Aluminum sheath, or lead alloy sheath, or Copper wire Screen,PVC or PE Outer sheath power cable


2.Cable property:

1)The maximum rated working temperature of conductor is 90°C, and the maximum temperature is less than 250°C when short circuit occurs(no more than 5 seconds
2)
Allowable maximum lateral pressure is 5KN/m.
3)
Allowable maximum traction strength of aluminum conductor is 40N/mm2.
4)Cable laying temperature is not less than 0°C.
5)The minimum bending radius is no less than 20D.

          (D---represents actual outer diameter of cable)

3.Type and Application:

66kv 110kv 220kv XLPE Insulated Hv Cable

4.Structure Drawing
66kv 110kv 220kv XLPE Insulated Hv Cable



5.Size range we produce:
66kv 110kv 220kv XLPE Insulated Hv Cable
6.Packing:
   Wooden Drum, Steel Wooden Drum, All Steel Drum for very heavy cable

Advantages of Brushless Dc Motor

  1. Brushless motors are more efficient as its velocity is determined by the frequency at which current is supplied, not the voltage.
  2. As brushes are absent, the mechanical energy loss due to friction is less which enhanced efficiency.
  3. BLDC motor can operate at high-speed under any condition.
  4. There is no sparking and much less noise during operation.
  5. More electromagnets could be used on the stator for more precise control.
  6. BLDC motors accelerate and decelerate easily as they are having low rotor inertia.
  7. It is high performance motor that provides large torque per cubic inch over a vast sped rang.
  8. BLDC motors do not have brushes which make it more reliable, high life expectancy, and maintenance free operation.
  9. There is no ionizing sparks from the commutator, and electromagnetic interference is also get reduced.
  10. Such motors cooled by conduction and no air flow are required for inside cooling.

Disadvantages of Brushless DC Motors

  1. BLDC motor cost more than brushless DC motor.
  2. The limited high power could be supplied to BLDC motor, otherwise too much heat weakens the magnets and insulation of winding may get damaged.

Brushless DC Gear Motor

Brushless Dc Gear Motor,Brushless Gear Motor,Brushless Electric Motor,Brushless Motor Controller

SHENZHEN DONGMING MOTOR CO., LTD. , http://www.dmdcmotor.com