• Model NO.: YJV
  • Conductor Type: Stranded
  • Conductor Material: Copper or Aluminum
  • Insulation Material: XLPE
  • Range of Application: Construction
  • Brand: Yifang
  • Color: Red , Black , Other as Per Requirement
  • Transport Package: Drum, Reel or According to Customers′ Request
  • Origin: Zhengzhou, Henan, China
  • Type: Insulated
  • Application: Overhead, Underground
  • Sheath Material: PVC
  • Material Shape: Round Wire
  • Certification: ISO9001, CE, CCC
  • Conductor No: 1 or 3
  • Trademark: Yifang
  • Specification: IEC, BS, DIN, ASTM, JIS, GOST, ETC
  • HS Code: 8544492100
6/10kv 12/20kv,18/30kv 2xsby/A2sxyby 95mm2 XLPE Cable

1. Brief Introduction of XLPE Insulated Power Cable
Cross-linked polyethylene insulated power cable not only has excellent electric, mechanical properties,
But also has powerful resistance against chemical corrosion, heat aging and environmental stress. Its structure
Is simple. The long term operating temperature is 90. It is convenient to use and can be laid with no
Restriction of different level.
Our enterprise can produce both flame retardant and non-flame retardant series of XLPE power cable.
Our XLPE Power cable covers all kinds of low-smoke low-halogen, low-smoke halogen free and three
Classes of A, B, C.
We can design and manufacture special XLPE cable according to the other standards required by the
Customers, such as Heavy section cut apart conductors, water-resistance, defend termites, defend mouse,
And so on.

2. Scope of our Cables
The rate voltage cables in the 1st class available
To the earth fault time within 1 minute. The cables
In the 2nd class are available to earth fault time not
Exceeding 2 hours generally, maximum time doesn't
Exceed 8 hours.

3. Service Conditions and Parameters of Cable
Max. Conductor Operating Temperature: 90
Short Circuit Temperature: 250 Not more than 5 seconds
Environmental temperature of operating: In air: 40
Underground: 25
Depth of laying in direct: 80cm
Thermal Resistance of soil: 100. Cm/W

Rated Voltage Uo/U KV 
Rated Voltage U0/U KV 0.6/1 1 1.8/3 3/3 3.6/6 6/6
6/10
8.7/10 8.7/15 12/20 18/20 18/30 21/35 26/35
Voltage Test Test Voltage KV 3.5 4.5 6.5 9.5 11 15 22 30 45 53 65
Test Time min 5 5 5 5 5 5 5 5 5 5 5
Partial Dischange Test Test Voltage KV _ _ _ _ 6.3 10.4 15.1 20.8 31.2 36.4 45
Dischange Capacity _ _ _ _ 20 20 20 20 20 20 20

Others I-Clamp (Quick Wire Connector)

Wire Connector for LED Lighting,Wire Connector for Wire Arrangement,Wire Connector for Quick Connection